The HG00-10-08-01R-VSC double gear pump has two fixed-displacement internal gear sections: 10.2 cc/rev at the front and 8.2 cc/rev at the rear. This double hydraulic pump uses a clockwise 9-tooth splined drive, a shared suction inlet and two separate outlets.

  • Front section: 10.2 cc/rev (size code 10).
  • Rear section: 8.2 cc/rev (size code 08).
  • Drive: 9-tooth spline and SAE two-bolt mounting flange.
  • Port arrangement: one shared suction inlet and two pressure outlets.

HG00-10-08-01R-VSC technical specifications

Use these catalogue dimensions to review the drive and port layout before ordering. For a replacement, compare the full nameplate code and the drawing for the quoted unit with the parts already installed on the machine.

Configuration reference for the HG00 10/08 tandem pump
Parameter Catalogue reference
Model designation HG00-10-08-01R-VSC
Pump type Fixed-displacement tandem internal gear pump, HG0 front and rear sections
Geometric displacement Front 10.2 cm³/rev, rear 8.2 cm³/rev
Input rotation Clockwise, viewed from the shaft end (R)
Drive shaft Spline (S), ANSI B92.1, 9 teeth, 16/32 DP, 30° pressure angle
Mounting flange SAE two-bolt (C), Ø82.55 mm pilot and 106.4 ± 0.2 mm mounting-hole centre distance on the VSC drawing
Installation dimensions Drawing dimensions A1 56 mm, A2 119.5 mm, A3 115.5 mm, A4 224.3 mm for front size 10 and rear size 08
Shared suction port Ø32 mm bore, 4 × M10 mounting threads, 17 mm deep, with 58.7 × 30.2 mm bolt spacing
Pressure outlets Two separate flange outlets. Confirm the flange dimensions and outlet positions on the quoted drawing.
Seal code V, fluororubber (FKM)
Rated pressure reference 315 bar (31.5 MPa) for each HG0 single-pump size in the catalogue. Confirm the combined-load limit for the tandem assembly.
Short-duration pressure reference 350 bar (35 MPa) for 10 seconds for each HG0 single-pump size. Confirm the applicable limits for the quoted assembly and duty cycle.
Speed reference 600–3,000 rpm for the corresponding HG0 single-pump sizes. Confirm tandem operating limits at the intended load and inlet conditions.
Assembled weight Confirm the net pump weight and packed shipping weight on the quotation.

The pressure and speed figures are reference data for the individual HG0 sections. Share both circuits’ pressure, speed and duty cycle so the tandem pump and drive can be reviewed for simultaneous loading.

At 1,500 rpm the two sections have calculated theoretical flows of 15.3 L/min at the front and 12.3 L/min at the rear. Use these figures for initial sizing. Actual flow depends on pressure, oil viscosity and volumetric losses. If both outlets work at once, share the flow and pressure required at each outlet and the operating speed at that point in the cycle.

Model code and replacement fit

Reading HG00 · 10 · 08 · 01R · VSC
Code Meaning
HG Internal gear pump family
00 HG0 frame at the front and rear
10 / 08 Front and rear displacement size codes, in that order
01 / R Design code 01 and clockwise input rotation
V / S / C Fluororubber seals, splined shaft and SAE two-bolt flange

VSC and VPC use different drive shafts. In the HG00 drawing, VSC uses a 9-tooth spline and VPC uses a keyed shaft. If you are replacing a pump with a keyway, send a shaft photo and the complete nameplate code so the coupling can be checked against the quoted version.

For a fit check, provide the pilot diameter, mounting-hole spacing, coupling type, port flange dimensions and outlet orientation. A photo showing the drive end and both sides of the assembly helps identify which fittings, adapters and hose clearances need to be checked. Use the original front and rear displacement order when requesting a replacement for two separate circuits.

Installation drawings

HG00 Double Gear Pump Suction Port Flange Dimensions

For an installation with tight clearances, ask for the approved drawing for the exact model and both outlets. Share the model number, coupling dimensions and the available space around the flange and hoses.

Applications for an HG00 double internal gear pump

Injection molding and plastics machinery

Where a machine uses two hydraulic circuits with different flow requirements, the tandem configuration gives each circuit its own pressure outlet. Share which functions run simultaneously and their flow and pressure requirements when you request selection support.

Die-casting equipment and industrial power units

For an existing power unit, check the motor adapter, coupling, suction connection and pressure flange positions. A drawing of the cabinet or pump mounting area helps confirm whether the replacement can use the existing pipework.

Servo-driven hydraulic systems

If the pump is driven by a variable-speed motor, provide the speed range during approach, working and holding phases. The shared suction inlet needs to be reviewed for the combined flow demand of both sections.

Frequently asked questions

What are the two displacements in this HG00 tandem pump?

The size codes are 10 at the front and 08 at the rear. The HG0 section table lists actual geometric displacements of 10.2 and 8.2 cm³/rev respectively.

What shaft does HG00-10-08-01R-VSC use?

The HG00 VSC drawing specifies a 9-tooth spline to ANSI B92.1, 16/32 DP with a 30° pressure angle. The keyed-shaft drawing is under the VPC suffix.

Can both sections run at 315 bar at the same time?

The catalogue lists 315 bar for each HG0 section as an individual reference. Provide the maximum load on each outlet and the time the two loads overlap so the assembled pump, drive and coupling can be reviewed for your duty cycle.

What should I send for a replacement quote?

Send the complete pump code, a readable nameplate photo, photos of the shaft and ports, the quantity and the delivery destination. If the original model code is incomplete, include the mounting and coupling dimensions.

Can I get a drawing and shipping details before ordering?

Request a drawing for the exact configuration along with lead time, package dimensions, gross weight and warranty terms. Include any inspection or documentation requirements in your enquiry.

HG00-10-08-01R-VSC Double Gear Pump

The HG00-10-08-01R-VSC double gear pump has two fixed-displacement internal gear sections: 10.2 cc/rev at the front and 8.2 cc/rev at the rear. This double hydraulic pump uses a clockwise 9-tooth splined drive, a shared suction inlet and two separate outlets.
  • Front section: 10.2 cc/rev (size code 10).
  • Rear section: 8.2 cc/rev (size code 08).
  • Drive: 9-tooth spline and SAE two-bolt mounting flange.
  • Port arrangement: one shared suction inlet and two pressure outlets.

HG00-10-08-01R-VSC technical specifications

Use these catalogue dimensions to review the drive and port layout before ordering. For a replacement, compare the full nameplate code and the drawing for the quoted unit with the parts already installed on the machine.

Configuration reference for the HG00 10/08 tandem pump
Parameter Catalogue reference
Model designation HG00-10-08-01R-VSC
Pump type Fixed-displacement tandem internal gear pump, HG0 front and rear sections
Geometric displacement Front 10.2 cm³/rev, rear 8.2 cm³/rev
Input rotation Clockwise, viewed from the shaft end (R)
Drive shaft Spline (S), ANSI B92.1, 9 teeth, 16/32 DP, 30° pressure angle
Mounting flange SAE two-bolt (C), Ø82.55 mm pilot and 106.4 ± 0.2 mm mounting-hole centre distance on the VSC drawing
Installation dimensions Drawing dimensions A1 56 mm, A2 119.5 mm, A3 115.5 mm, A4 224.3 mm for front size 10 and rear size 08
Shared suction port Ø32 mm bore, 4 × M10 mounting threads, 17 mm deep, with 58.7 × 30.2 mm bolt spacing
Pressure outlets Two separate flange outlets. Confirm the flange dimensions and outlet positions on the quoted drawing.
Seal code V, fluororubber (FKM)
Rated pressure reference 315 bar (31.5 MPa) for each HG0 single-pump size in the catalogue. Confirm the combined-load limit for the tandem assembly.
Short-duration pressure reference 350 bar (35 MPa) for 10 seconds for each HG0 single-pump size. Confirm the applicable limits for the quoted assembly and duty cycle.
Speed reference 600–3,000 rpm for the corresponding HG0 single-pump sizes. Confirm tandem operating limits at the intended load and inlet conditions.
Assembled weight Confirm the net pump weight and packed shipping weight on the quotation.

The pressure and speed figures are reference data for the individual HG0 sections. Share both circuits’ pressure, speed and duty cycle so the tandem pump and drive can be reviewed for simultaneous loading.

At 1,500 rpm the two sections have calculated theoretical flows of 15.3 L/min at the front and 12.3 L/min at the rear. Use these figures for initial sizing. Actual flow depends on pressure, oil viscosity and volumetric losses. If both outlets work at once, share the flow and pressure required at each outlet and the operating speed at that point in the cycle.

Model code and replacement fit

Reading HG00 · 10 · 08 · 01R · VSC
Code Meaning
HG Internal gear pump family
00 HG0 frame at the front and rear
10 / 08 Front and rear displacement size codes, in that order
01 / R Design code 01 and clockwise input rotation
V / S / C Fluororubber seals, splined shaft and SAE two-bolt flange

VSC and VPC use different drive shafts. In the HG00 drawing, VSC uses a 9-tooth spline and VPC uses a keyed shaft. If you are replacing a pump with a keyway, send a shaft photo and the complete nameplate code so the coupling can be checked against the quoted version.

For a fit check, provide the pilot diameter, mounting-hole spacing, coupling type, port flange dimensions and outlet orientation. A photo showing the drive end and both sides of the assembly helps identify which fittings, adapters and hose clearances need to be checked. Use the original front and rear displacement order when requesting a replacement for two separate circuits.

Installation drawings

HG00 Double Gear Pump Suction Port Flange Dimensions

For an installation with tight clearances, ask for the approved drawing for the exact model and both outlets. Share the model number, coupling dimensions and the available space around the flange and hoses.

Applications for an HG00 double internal gear pump

Injection molding and plastics machinery

Where a machine uses two hydraulic circuits with different flow requirements, the tandem configuration gives each circuit its own pressure outlet. Share which functions run simultaneously and their flow and pressure requirements when you request selection support.

Die-casting equipment and industrial power units

For an existing power unit, check the motor adapter, coupling, suction connection and pressure flange positions. A drawing of the cabinet or pump mounting area helps confirm whether the replacement can use the existing pipework.

Servo-driven hydraulic systems

If the pump is driven by a variable-speed motor, provide the speed range during approach, working and holding phases. The shared suction inlet needs to be reviewed for the combined flow demand of both sections.

Frequently asked questions

What are the two displacements in this HG00 tandem pump?

The size codes are 10 at the front and 08 at the rear. The HG0 section table lists actual geometric displacements of 10.2 and 8.2 cm³/rev respectively.

What shaft does HG00-10-08-01R-VSC use?

The HG00 VSC drawing specifies a 9-tooth spline to ANSI B92.1, 16/32 DP with a 30° pressure angle. The keyed-shaft drawing is under the VPC suffix.

Can both sections run at 315 bar at the same time?

The catalogue lists 315 bar for each HG0 section as an individual reference. Provide the maximum load on each outlet and the time the two loads overlap so the assembled pump, drive and coupling can be reviewed for your duty cycle.

What should I send for a replacement quote?

Send the complete pump code, a readable nameplate photo, photos of the shaft and ports, the quantity and the delivery destination. If the original model code is incomplete, include the mounting and coupling dimensions.

Can I get a drawing and shipping details before ordering?

Request a drawing for the exact configuration along with lead time, package dimensions, gross weight and warranty terms. Include any inspection or documentation requirements in your enquiry.

Related products